Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 11/03/2000 |
BUILDING - FINAL |
|
Approved |
IVRS - Inspection 0000* |
| 11/01/2000 |
BUILDING - FINAL |
|
Denied |
IVRS - Inspection 0999*/1. NO PART OF A FLEX CONNECTION MAY ENTER THE FURNACE CAVITY. 2. REMOVE ELECTRIC LINE WITHIN ATTIC ACCESS. 3. PROVIDE MIN 3 SCREWS AT FLUE CONNECTION. 4. GAS LINE NOT SUPPORTED. |
| 10/31/2000 |
BUILDING - FINAL |
|
Not ready for Inspection |
IVRS - Inspection 0000*/1. PROVIDE PERMANENT ATTACHMENT OF GAS RISER TO HOUSE. (PARALELL EXTENSION). 2. COMPLETE STUCCO REPAIR AT EXHAUST HOOD VENT. 3. PROVIDE PLASTIC TO ACCESS HOUSE FIELD CONDITIONS EXCESSIVELY MUDDY. |