Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
10/26/2000 FRAMING Approved IVRS - Inspection 0000*
10/23/2000 FRAMING Denied IVRS - Inspection 0999*/1. KITCHEN LAYOUT DOES NOT MATCH APPROVED PLAN (PROVIDE APPROVED REVISION) 2. ISLAND VENTING ONLY PERMITTED WHERE NOT POSSIBLE TO VENT THROUGH ROOF. 3. SHEARWALL AT BACK OF GARAGE NOT PER PLAN SEE 13/DI AND 17/01. 4. AIR REGISTERS MUST BE SUPPORTED (BLOCK 3 SIDES). 5. REFER LINES INCOMPLETE. 6. PEX LINES PENETRATING STEEL MUST BE PROTECTED. 7. AT KITCHEN HIP INSTERSECTION, ANCHOR GUSSET TO COMMON. 8. BRACE STUB TRUSSES PER 8/DI. 9. STUCCO MESH INCOMPLETE.