Permit: T00CM02164

Parcel: 113094890

Inspection Status: Approved

Inspection History: BUILDING - FINAL

Permit Number - T00CM02164

Inspection Description - BUILDING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
05/09/2001 BUILDING - FINAL Approved IVRS - Inspection 0000*
04/26/2001 BUILDING - FINAL Denied IVRS - Inspection 0999*/1) PROVIDE 2 PERCENT GRADE FROM FOUNDATION OUT 5 FT AROUND HOUSE 2) ELEC SRVC PANEL REQ'S NON WATER BOND LABEL 3) DISHWASHER AND DISPOSAL ARE ON A MULTI WIRE BRANCH CIRCUIT COMPLY WITH NEC SECTION 210-4B 4) TRIM CLEAN OUTS TO GRADE 5) ABS PLASTIC VENTS ON ROOF MUST BE PROTECTED WITH LATEX PAINT 6) PROTECT EXPOSED PLUMBING AT SLAB EXTERIOR SE CORNER 7) AN EXCESS OF 48" EXISTS BETWEEN ELEC OUTLETS WEST KITCHEN COUNTER 8) GRADING AND PARKING NOT COMPLETE