Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 05/09/2001 |
BUILDING - FINAL |
|
Approved |
IVRS - Inspection 0000* |
| 04/26/2001 |
BUILDING - FINAL |
|
Denied |
IVRS - Inspection 0999*/1) PROVIDE 2 PERCENT GRADE FROM FOUNDATION OUT 5 FT AROUND HOUSE 2) ELEC SRVC PANEL REQ'S NON WATER BOND LABEL 3) DISHWASHER AND DISPOSAL ARE ON A MULTI WIRE BRANCH CIRCUIT COMPLY WITH NEC SECTION 210-4B 4) TRIM CLEAN OUTS TO GRADE 5) ABS PLASTIC VENTS ON ROOF MUST BE PROTECTED WITH LATEX PAINT 6) PROTECT EXPOSED PLUMBING AT SLAB EXTERIOR SE CORNER 7) AN EXCESS OF 48" EXISTS BETWEEN ELEC OUTLETS WEST KITCHEN COUNTER 8) GRADING AND PARKING NOT COMPLETE |