Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T00CM02164

Parcel: 113094890

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T00CM02164

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
02/13/2001 FRAMING Approved IVRS - Inspection 0000*/OK TO DRYWALL.
02/02/2001 FRAMING Denied IVRS - Inspection 0999*/1. 8 STUDS ON EXTERIOR WALLS ARE NOT IN CONTACT OR BEARING ON SILL PLATE. 2. 2 FIRE BLOCKS MISSING MASTER B/R AT CEILING.
01/12/2001 FRAMING Denied IVRS - Inspection 0950*/1. HOLD DOWNS MUST BE ATTACHED TO FULL LENGTH DOUBLE STUDS NOT CRIPPLES, TRIMMERS OR SINGLE STUDS. PROVIDE ENGINEERS APPROVED REPAIR FOR 5 LOCATIONS. 2. BLOCK TRUSSES AT BOTTOM CHORD PER 4/5. 3. NAILERS REQUIRE H3 CLIPS PER 6/5. 4. NO PRESSURE TEST ON PLUMBING AND LOW PRESSURE TEST ON GAS. 5 SECURE 4 SWITCH ELECT A.C. BOX ON 2 ENDS. 6. "0" CLEARANCE FIRE PLACE DAMAGED/CRUSHED. PROVIDE MANUFACTURES ENGINEER AND C.O.T. APPROVAL OF REPAIR OR REPLACE. 7. FIREPLACE VENT IMPROPERLY INSTALLED AND IN CONTACT WITH WOOD 8. REVERSE FLOW ON LAV TRAP ARM. 9. STUDS ON EXTERIOR WALLS MUST BEAR ON SILL PLATES.