Permit: T00CM02161

Parcel: 125060900


Addresses:

1945 E 5TH ST

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
11/03/2000 FRAMING Approved IVRS - Inspection 0000*
08/17/2000 FRAMING Partial Approval IVRS - Inspection 0000*/ADDITION OK LAUNDRY AND DINING ROOM REMODEL NOT READY.
08/16/2000 FRAMING Denied IVRS - Inspection 0999*/1. NO CITY OF TUCSON APPROVED PLANS ON SITE. 2. LEDGER BOLTS LOOSE WEST WALL CHECK ALL 3. 4 SWITCH ELECTRIC BOX NORTH SIDE OF EXTERIOR DOOR MUST BE BLOCKED AT BOTH ENDS. 4. DEMOLITION OF SOUTHWALL NOT COMPLETE. NEXT FAILURE WILL BE CHARGED A REINSPECTION FEE.
08/15/2000 FRAMING Denied IVRS - Inspection 0999*/1. NO CITY OF TUCSON APPROVED PLAN ON SITE. 2. SUPPORT 4 SWITCH ELECTRIC BOX ON 2 ENDS 3. LEDGER BOLT LOOSE N. W. CORNER CHECK ALL 4. 2 X 12 LEDGER/RAFTER SOUTHWALL NOT SUPPORTED AT WEST END. 5. DEMO OF EXISTING NOT COMPLETE.
08/08/2000 FRAMING Partial Approval IVRS - Inspection 0000*/OK TO DECK
08/07/2000 FRAMING Denied IVRS - Inspection 0925*/1. YOU ARE REQUIRED MINIMUM OF 12" CLEARANCE BETWEEN FLOOR TRUSS JOIST AND SOIL OR TREATED MATERIALS. UBC 2317.3 2. YOU HAVE ELIMINATED THE EXISTING HOUSE CRAWL SPACE ACCESS YOU MUST PROVIDE A NEW ACCESS FOR THE EXISTING AND ONE FOR THE ADDITON PER UBC 2317.3 SIZE 18X24. 3. MANY FLOOR AND ROOF JOIST ARE TOO SHOR MUST BEAR FULLY ON HANGER BOTTOM PER SIMPSON INSTALLATION INST. NO PLANS ON SITE STOPPED INSP.