Permit: T00CM02111

Parcel: 11931023G

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
08/01/2001 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
07/12/2001 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection 0000*/ 1) OK-TO DRY IN ROOF, PENDING ARCHITECTS APPROVAL ON SECURING ROOF SHEATHIN WITH NAILS IN LIEU OF SCREWS
07/09/2001 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) STUD AND JOIST INSTALLED ACCORDING TO PLAN SPLICE REINFORCEMENTS NOT PROVIDED, IN LINE FRAMING NOT INSTALLED AS PER PLAN 2) FIELD MODIFICATIONS WILL REQUIRE APPROVAL FROM THE ENGINEER OF RECORD OR BUILD PER PLAN 3) SET BACKS AND CLEARANCES FROM ASCENDING AND DESCENDING SLOPES MAY REQUIRE SPECIAL ENGINEERING IN ORDER TO COMPLY WITH SEC R403.1.7.4 4) C CHANNELS AT FLOOR TO FLOOR CONNECTIONS NOT INSTALLED TAUT STRAPS NOT INSTALLED, I BEAM HEADERS REQUIRE INSULATION AT EXTERIOR 5) STUD FACTORY KNOTCH OUT FROM BOTTOM TRACK IS MINIMUM 2' INSTALLATION NOT CORRECT