Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date |
Description |
Inspector |
Results |
Comments |
| 08/01/2001 |
EXT METAL CLIPS/EXT SHEATHING |
|
Approved |
IVRS - Inspection 0000* |
| 07/12/2001 |
EXT METAL CLIPS/EXT SHEATHING |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) OK-TO DRY IN ROOF, PENDING ARCHITECTS APPROVAL ON SECURING ROOF SHEATHIN WITH NAILS IN LIEU OF SCREWS |
| 07/09/2001 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999*/ 1) STUD AND JOIST INSTALLED ACCORDING TO PLAN SPLICE REINFORCEMENTS NOT PROVIDED, IN LINE FRAMING NOT INSTALLED AS PER PLAN 2) FIELD MODIFICATIONS WILL REQUIRE APPROVAL FROM THE ENGINEER OF RECORD OR BUILD PER PLAN 3) SET BACKS AND CLEARANCES FROM ASCENDING AND DESCENDING SLOPES MAY REQUIRE SPECIAL ENGINEERING IN ORDER TO COMPLY WITH SEC R403.1.7.4 4) C CHANNELS AT FLOOR TO FLOOR CONNECTIONS NOT INSTALLED TAUT STRAPS NOT INSTALLED, I BEAM HEADERS REQUIRE INSULATION AT EXTERIOR 5) STUD FACTORY KNOTCH OUT FROM BOTTOM TRACK IS MINIMUM 2' INSTALLATION NOT CORRECT |