Permit: T00CM01989

Parcel: 131031800


Addresses:

5224 E 28TH ST

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
10/30/2000 ELECTRIC - FINAL Approved IVRS - Inspection 0000*
10/17/2000 ELECTRIC - FINAL Denied IVRS - Inspection 0999$/1. REAR STOOP. 2. BUSHING IN SERV PANEL. 3. BACK CHECK DEVICE AT HOSE BIB. 4. OUTLET IN BED HATS AN OPEN GRD. 5. ROOF JACKS ON ROOF PENETRATIONS. 6. T & P LINE TIED INTO CONDENSATE 7. MIN. SIZE ROOF VENT IS 2" USE CORRECT FITTING FOR CONDENSATED DRAIN. SAN T B REDUCER. 8. NEED 16" X 5" RELIEF DUCT IN MECH. ROOM, USE CORRECT TAPE ON FLUE JOINTS.
09/07/2000 ELECTRIC - FINAL Not ready for Inspection IVRS - Inspection 0000*/1. 2 BOXES THAT NEED WIRE NUTS AND COVER PLATES AT SKY LITES. 2. LABEL YOU SERV. PANEL CIRCUITS. 3. NEED A GAS, AND H20 BOND. 4. GARAGE LIGHT NEEDS FIXTURE OR BOX AND COVER PLATE. 5. NEED H.A.V.C INSTALLED.