Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 09/18/2000 |
BUILDING - FINAL |
|
Approved |
IVRS - Inspection 0000* |
| 09/13/2000 |
BUILDING - FINAL |
|
Denied |
IVRS - Inspection 0999*/1. A/C CONDENSATE CANNOT BE INSTALLED BY DRILLING ABS WASTE VENT. YOU SHOULD CUT WASTE VENT AT BOTTOM OF DRILLED HOLE AND INSTALL A SANITARY "T" WITH A REDUCER TO 3/4" SIDE INLET DO NOT BLOCK VENT. 2. PAINT ABS PLASTIC VENT ON ROOF. 3. OUTSIDE HOSE BIBS REQUIRE ANTISIPHON VALVE. 4. ALL KITCHEN COUNTER OUTLETS MUST BE GFCI PROTECTION. 5. DRYER MUST HAVE 4 PRONG OUTLET. 6. NON USED GAS VALVES MUST BE PLUGGED/CAPPED. |