Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
09/12/2000 BUILDING - FINAL Partial Approval REMOVE METAL TAPE AT SINGLE TO DOUBLE WALL FLUE PIPE CONNECTION ON HOT WATER
PROVIDE 1/4" MESH IN BOTH COMBUSTION VENTS AT HOT WATER ROOM (SEE UMC 704.3 702.3)
PROVIDE CAP TO GAS LINE VALVE FOR FUTURE DRYER
PROVIDE VENTILATION WASHER DRYER ROOM MECHANICAL OR OPENABLE WINDOW (SEE USB 1203.3 CHAPTER 3
09/01/2000 BUILDING - FINAL Partial Approval 1. REMOVE METAL TAPE AT SINGLE TO DOUBLE WALL FLUE PIPE CONNECTION ON HOT WATER. 2. PROVIDE 1/4" MESH IN BOTH COMBUSTION VENTS AT HOT WATER ROOM. (SEE UMC 704.3 702.3) 3. PROVIDE CAP TO GAS LINE VALVE FOR FUTURE DRYER. 4. PROVIDE VENTILATION TO WASHER/DRYER ROOM, MECHANICAL OR OPENABLE WINDOW (SEE UBC 1203.3 CHAPTER 3).