Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/06/2001 | ELECTRIC - FINAL | Approved | IVRS - Inspection 0000* | |
| 04/03/2001 | ELECTRIC - FINAL | Denied | IVRS - Inspection 0999* NEED PROPER CLEARANCE IN FRONT OF A/C 3'X30" | |
| 03/20/2001 | ELECTRIC - FINAL | Denied | 1) STRAP #4 WIRE FROM SERVICE TO GAS LINES - TO FLOOR OR WALL 2) UNIT #3 CIRCUIT 13 YOU HAVE 1 #10 ON 25A 2POLE CIRCUIT-SHOULD BE ON 1 POLE CB-ALSO NOT MARKED IN PANEL SCHEDULE 3) A/C UNITS COMPRESSORS OUTSIDE REQUIRE 3' IN FRONT OF CLEAR TO GRADE ALSO NO TRIPPING HAZARDS. ALL UNITS TAPE WHITE AS HOT CONDUCTOR 4) WERE BOXES BEHIND FIXTURES IN BATHROOMS RELOCATED? BOX ALSO 5) UNIT #2 2 POLE 25A CB USED WHERE1 POLE SHOULD BE PANEL SCHEDULE INCORRECT #6 EMPTY, 16 EMPTY 6) BATHROOM LIGHTS INCORRECTLY MOUNTED NEED BOX BEHIND FIXTURES |
|
| 03/16/2001 | ELECTRIC - FINAL | Denied | 1) NEED TO HAVE HORDS INSTALLED 2) ONE HORD INSTALLED ROMEX WIRE COMPRESSED AGAINST WALL BOARD AND HOOD 3) NEED ROMEX CONNECTOR |