Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 11/13/2000 |
BUILDING - FINAL |
|
Approved |
IVRS - Inspection 0000* |
| 11/08/2000 |
BUILDING - FINAL |
|
Partial Approval |
IVRS - Inspection 0000*/1. LABEL ALL CIRCUITS IN ELECTRIC PANEL WITH PERMANENT INK. 2. PROVIDE A BLANK PLATE TO FACE OR SERVICE COVER (ELECTRIC) AND SECURE WITH SCREW. 3. PROVIDE A SCREW TO GFCI WEATHER PROTECTIVE COVER. 4. RECEPT ON FRONT PORCH NEED TO BE GFCI. 5. PROVIDE GFCI IN CAR PORT. 6. PROVIDE CAP TO STOVE FLEX GAS LINE OR CONNECT TO APPLIANCE. 7. COMPLETE ELECTRIC IN SHED. 8. KITCHEN STOVE CAN NOT BE ON THE SMALL APPLIANCE GFCI CIRCUIT. 9. THE REFRIGERATOR CAN NOT BE ON THE LOAD SIDE OF THE GFCI CIRCUIT. 10. SEAL ALL DUCT PENETRATIONS AT CEILING IN FURNACE ROOM. 11. SMOKE ALARM IN HALLWAY NOT WORKING, THEY ARE NOT WORKING ANYWHERE IN THE HOUSE. |