Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
Permit Number - T00CM01748
Inspection Description - ELECTRIC - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/14/2001 | ELECTRIC - FINAL | Approved | IVRS - Inspection 0000* | |
10/04/2001 | ELECTRIC - FINAL | Denied | IVRS - Inspection 0999*1.) SUPPORT ALL FIXTURES WITH SUPPORT WIRES AS REQUIRED 2.) LOOSE FITTINGS 3.) SUPPORT M/C CABLE AS PER CODE. 4.) DATA LAYING ON GRID. 5.) OPEN JUNCTION BOX ABOVE CEIL AND EXPOSED 277V CONDUCTORS. 6.) CONNECTION FITTINGS LOOSE USE PLATES THAT WILL SUPPORT FITTINGS. | |
10/03/2001 | ELECTRIC - FINAL | Denied | IVRS - Inspection 0920*IVR DOWN COULD NOT RETREVE MESSAGE NEED ACCESS TO ALL AREAS TO BE INSPECTED PLEASE PROVIDE STEP LADDER FOR INSPECTIONS NEED TO BE RECALLED BY 10-4-01 | |
10/01/2001 | ELECTRIC - FINAL | Partial Approval | IVRS - Inspection 0000* | |
09/21/2001 | ELECTRIC - FINAL | Denied | IVRS - Inspection 0935* | |
09/20/2001 | ELECTRIC - FINAL | Denied | IVRS - Inspection 0245* | |
09/11/2001 | ELECTRIC - FINAL | Denied | IVRS - Inspection 0935* | |
08/28/2001 | ELECTRIC - FINAL | Denied | IVRS - Inspection 0999* | |
07/22/2001 | ELECTRIC - FINAL | Not ready for Inspection | IVRS - Inspection 0000*CANCEL BY FRANK | |
07/19/2001 | ELECTRIC - FINAL | Not ready for Inspection | IVRS - Inspection 0000* | |
07/12/2001 | ELECTRIC - FINAL | Denied | IVRS - Inspection 0999* | |
03/16/2001 | ELECTRIC - FINAL | Partial Approval | IVRS - Inspection 0000* 1) ATTACH FIXTURES TO GRID 2) STRAP FLEX CONDUIT AS PER CODE 3) ATTCH SUPPORT WIRES TO FIXTURES ROOM # WEST. OK SUBJECT TO INSP MANAGER DETERMINATION 4TH FLOOR | |
03/15/2001 | ELECTRIC - FINAL | Partial Approval | IVRS - Inspection 0000* 1) MISSING COVERS FOR POWER POLES 2) FILL ALL UNUSED OPENINGS 3) EXPOSED CONDUCTORS CAP AND INSTALL COVERS 4) SUPPORT CONDUIT AS PER CODE 5) INSTALL ALL TRAY COVERS 6) REVISE PANEL SCHEDULES | |
03/13/2001 | ELECTRIC - FINAL | Not ready for Inspection | IVRS - Inspection 0000* |