Inspection Status: Partial Approval
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 02/28/2001 |
FRAMING |
|
Partial Approval |
IVRS - Inspection 0000*/STILL NEED TO FRAME TO ROOF CONNECTION |
| 02/05/2001 |
FRAMING |
|
Not ready for Inspection |
IVRS - Inspection 0000*/1. ALL OSB TO BE BLOCKED 2' O.C. TWO NAILS EACH END. 2. BRACES NOT AS HIGH ON THE VERTICAL MEMBER AS POSSIBLE. 3. NEED U VALUE OF WINDOWS, IN WRITING FROM THE PLACE YOU BOUGHT THEM. 4. SIDING NOT NAILED NEED BACKING 2' O.C. |
| 02/01/2001 |
FRAMING |
|
Not ready for Inspection |
IVRS - Inspection 0000*/1. X BRACE TRUSSES AT EACH END AND AT THE MIDDLE. 2. BLOCKS AT 2' O.C. AND JOINT FOR ALL O.S.B. RUN PARALELL TO TRUSS 3. BLOCK AT EAST WALL ON TOP OF WALL. 4. NAIL ALL GABLE END SIDING, INSTALL NAILERS. 5. FILL OUT R. VALUE CHART FOR WINDOW INSP. |