Permit: T00CM01741

Parcel: 126130660


Addresses:

4558 E COOPER ST

Inspection Status: Partial Approval

Inspection History: FRAMING

Date Description Inspector Results Comments
02/28/2001 FRAMING Partial Approval IVRS - Inspection 0000*/STILL NEED TO FRAME TO ROOF CONNECTION
02/05/2001 FRAMING Not ready for Inspection IVRS - Inspection 0000*/1. ALL OSB TO BE BLOCKED 2' O.C. TWO NAILS EACH END. 2. BRACES NOT AS HIGH ON THE VERTICAL MEMBER AS POSSIBLE. 3. NEED U VALUE OF WINDOWS, IN WRITING FROM THE PLACE YOU BOUGHT THEM. 4. SIDING NOT NAILED NEED BACKING 2' O.C.
02/01/2001 FRAMING Not ready for Inspection IVRS - Inspection 0000*/1. X BRACE TRUSSES AT EACH END AND AT THE MIDDLE. 2. BLOCKS AT 2' O.C. AND JOINT FOR ALL O.S.B. RUN PARALELL TO TRUSS 3. BLOCK AT EAST WALL ON TOP OF WALL. 4. NAIL ALL GABLE END SIDING, INSTALL NAILERS. 5. FILL OUT R. VALUE CHART FOR WINDOW INSP.