Permit: T00CM01739

Parcel: 122132130


Addresses:

1660 N ALVERNON WY

Inspection Status: Approved

Inspection History: MECHANICAL - ABOVE CEILING

Date Description Inspector Results Comments
06/19/2001 MECHANICAL - ABOVE CEILING Approved IVRS - Inspection 0000*REMOVE VENT FROM CONDENSATE TRAP OR INSTALL DOWNSTREAM OF TRAP.SEE SEC. 310.3 1994 UMC CODE MODIFICATIONS.WILL CHECK ON FINAL.
06/13/2001 MECHANICAL - ABOVE CEILING Not ready for Inspection IVRS - Inspection 0000*
06/12/2001 MECHANICAL - ABOVE CEILING Partial Approval IVRS - Inspection 0000*1)STRAP FLEX DUCT UP OFF OF LIGHT IN ROOM AT END OF 1ST FLOOR.2)AIR HANDLER LOCATION NOT PER PLAN.PROVIDE ADEQUATE CLEARANCE TO SERVICE ACCESS PANEL AND FILTER.3)PIPE SECONDARY DRAIN TO A READILY VISIBLE LOCATION.4)PROVIDE HOSE CLAMPS ON CONSATE PUMP HOSE.5)PROVIDE A TRAP ON CONDENSATE DRAIN LINE.