Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 07/18/2001 |
PLUMBING - FINAL |
|
Approved |
IVRS - Inspection 0000*1.) PLBG FINAL IS OK 2.) OK FOR C OF O. |
| 07/17/2001 |
PLUMBING - FINAL |
|
Denied |
IVRS - Inspection 0999*1.) H.C. FLUSH VALVE FOR URINIAL MUST BE MIN 6" ABOVE TO P OF URINAL TO C.L. ON DISCHARGE TUBE SEE SECTION: 603.3.1 94 UPC 2.) WATER CLOSETS IN WOMENS RM MUST HAVE MIN OF 15" SIDE CLEARANCE SEE SECTION: 408:5 94 UPL 3.) H.C. WATER CLOSET HANDLE MUST BE ON OPEN SIDE OF STALL (ADA SPECS) 4.) C.O. IN MENS WATER CLOSET MUST HAVE NO OSTRUCTION 18" MIN TO FRONT OF C.O. 5.) HOT SUPPLY ON WOMENS LAV MUST HAVE WRAP. 6.) MUST STRAP DOWN EXPANSION TANK FOR WATER HTR. 7.) MUST CAULK MOP SINK. |