Permit: T00CM01739

Parcel: 122132130


Addresses:

1660 N ALVERNON WY

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Date Description Inspector Results Comments
07/19/2001 PLUMBING - ROUGH, SOIL Approved
05/11/2001 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection 0000*
04/17/2001 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection 0000*1. SOIL WATER TEST OK, 2.BLDG DRAIN IS STUBBED OUT OF BLDG. ONLY.3. OK TO BACKFILL TRENCH 4. NOTE: WILL REQUIRE REVISED & APPROVED DRAWING ON WASTE & VENT SYSTEM BEFORE NEXT INSPECTION. 5. MOP SINK NOT ROUGHED IN AT THIS TIME.
04/13/2001 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection 0999* 1) MUST PROVIDE A 10' HEAD ON SOIL WATER TEST SEE SECTION:712.2 94 UPC
2) SEE SEC 706.2 FOR BACK TO BACK WATER CLOSETS