Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/19/2000 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection 0000* 1. ALL CORRECTIONS MADE SATISFACTORILY 2. WATER TEST OK 3. OK TO COVER WALLS |
|
| 09/13/2000 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection 0999* ONLY WE AND TUB ON ONE UNIOT WATER TESTED TUB SHOE LEAKING NO HUB BAND NOT APPROVED FOR CONNECTING ABS TO ABS READ SECTION 1002.4 94" UPC OBTH UPSTAIRS TUBS NO APPROVED PLANS ON SIGHT MAY NEED ADDITIONAL BRACES AND SUPPORTS |
|
| 08/15/2000 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection 0999* MUST TEST WASTE AND VENT SYSTEM TRAP ARM FOR TUB AND SHOWER HAS A OFFSET MAKEING IT A RUNNING TRAP |
|
| 07/21/2000 | PLUMBING - INTERMEDIATE | Not ready for Inspection | 1. PLEASE PROVIDE AS BUILD DRAWINGS NOT PER PLAN AT THIS TIME AND NO TEST PLEASE SEE WATER HEATER LOCATION CODE VIOLATIONS ON REFIEF LINES TO WATER HEATERS TRAPPED WILL NEED TEST ABS AT TIME OF INSPECTION |