Permit: T00CM01704

Parcel: 126010520


Addresses:

920 N BELVEDERE AV

Inspection Status: Approved

Inspection History: ELECTRIC - INTERMEDIATE

Date Description Inspector Results Comments
11/02/2000 ELECTRIC - INTERMEDIATE Approved IVRS - Inspection 0000*
10/30/2000 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection 0245*
TYPE SJ CORD IS NOT APPROVED FOR PERMANENT WIRING CONCEALED IN WALLS. REPLACE FOR MOTOR AND A 14 FOR THE PUMP
10/20/2000 ELECTRIC - INTERMEDIATE Partial Approval 10/20/00 OK WALLS, CEILINGS EXCEPT 2-GANG BOX FOR COOLER OVER FILLED CANNOT EXCEED 12# 12 CONDUCTORS*
10/17/2000 ELECTRIC - INTERMEDIATE Denied THE ROMEX CABLE MUST HAVE A STAPLE NEAR WHERE IT ENTERS THE BOX. OK TO GROUP AND BUNDLE W/TIE AND STAPLE OFF.
GROUND WIRES MUST BE CRIMPED TOGETHER WITH A CRIMP SLEEVE. TWISTING ONLY IS NOT ACCEPTABLE
WIRE OUT OF WALL AT BATHROOM
USE "BANG PLATES" TO PROTECT ROMEX IN STUDS WHERE THE HOLE IS CLOSER TO WALL THAN CENTER OF STUD RECALL WHEN CORRECTED
10/09/2000 ELECTRIC - INTERMEDIATE Denied IN PANEL NEUTRAL AND GROUND NOT TO BE TIED TOGETHER
STAPLE ALL ROMEX WITHIN 12" OF BOXES
MAKE UP ALL BOXES, TIE GORUNDS AND NEUTRALS
PENISULA ELECTRICAL RANGE RECEPTACLE ON WRONG WALL NO PROVISIONS FOR RECEPTACLES AT END
09/29/2000 ELECTRIC - INTERMEDIATE Denied CONDUCTORS TO SHORT IN STAIRWAY LIGHT BOX
NO PLANS ON SITE
ASKED THE ELECTRICIAN SOME QUESTIONS ABOUT WIRING ON 09/28/00 HIS REPLY WAS, I DON'T KNOW I DIDN'T READ THE PLANS A REINSPECTION FEE IS ASSESTED
09/27/2000 ELECTRIC - INTERMEDIATE Not ready for Inspection IVRS - Inspection 0000*
INSTALL SMOKE DETECTOR WIRING AND BOXES, MUST BE INTER CONNECTED.
BATHROOM WALL LIGHT
RANGE RECEPTACLE
VERIFY VOLTAGE FOR BASE BOARD
HEATERS AND WIRE ACCORDINGLY DO NOT SHARE 240 V CIRCUIT WITH 110 V RECEPTACLES
09/13/2000 ELECTRIC - INTERMEDIATE Not ready for Inspection IVRS - Inspection 0000*
08/15/2000 ELECTRIC - INTERMEDIATE Denied