Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T00CM01654
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/27/2000 | FRAMING | Approved | IVRS - Inspection 0000* | |
09/07/2000 | FRAMING | Denied | IVRS - Inspection 0999*/1. OUTSIDE ELECTRIC BOXES NOT IN MUST BE INSTALLED. 2. MAKE UP ALL ELECTRIC GROUNDS IN BOXES AND SECURE WITH MECHANICAL FASTENER. 3. INSTALL W/C FLOOR FLANGE. 4. BACK GROUT/SEAL FLOOR PENETRATIONS TUBS AND VALVES NOT IN. 5. COPPER PLUMBING CANNOT BE IN CONTACT WITH IRON GAS PIPE. 6. MECH NOT IN 7. BOND GAS AND COPPER PLUMB. WITH #4 COPPER WITH CONNECTION EXPOSED. 8. KITCHEN TRAP ARM TRAP CANNOT BE ABOVE VENT OPENING. 9. SUPPORT 3/4 GAS LINE AT 8' O.C. AND ALL ELBOWS. |