Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 09/27/2000 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 09/07/2000 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/1. OUTSIDE ELECTRIC BOXES NOT IN MUST BE INSTALLED. 2. MAKE UP ALL ELECTRIC GROUNDS IN BOXES AND SECURE WITH MECHANICAL FASTENER. 3. INSTALL W/C FLOOR FLANGE. 4. BACK GROUT/SEAL FLOOR PENETRATIONS TUBS AND VALVES NOT IN. 5. COPPER PLUMBING CANNOT BE IN CONTACT WITH IRON GAS PIPE. 6. MECH NOT IN 7. BOND GAS AND COPPER PLUMB. WITH #4 COPPER WITH CONNECTION EXPOSED. 8. KITCHEN TRAP ARM TRAP CANNOT BE ABOVE VENT OPENING. 9. SUPPORT 3/4 GAS LINE AT 8' O.C. AND ALL ELBOWS. |