Permit: T00CM01654

Parcel: 115071810


Addresses:

35 E ADAMS ST


Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T00CM01654

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
09/27/2000 FRAMING Approved IVRS - Inspection 0000*
09/07/2000 FRAMING Denied IVRS - Inspection 0999*/1. OUTSIDE ELECTRIC BOXES NOT IN MUST BE INSTALLED. 2. MAKE UP ALL ELECTRIC GROUNDS IN BOXES AND SECURE WITH MECHANICAL FASTENER. 3. INSTALL W/C FLOOR FLANGE. 4. BACK GROUT/SEAL FLOOR PENETRATIONS TUBS AND VALVES NOT IN. 5. COPPER PLUMBING CANNOT BE IN CONTACT WITH IRON GAS PIPE. 6. MECH NOT IN 7. BOND GAS AND COPPER PLUMB. WITH #4 COPPER WITH CONNECTION EXPOSED. 8. KITCHEN TRAP ARM TRAP CANNOT BE ABOVE VENT OPENING. 9. SUPPORT 3/4 GAS LINE AT 8' O.C. AND ALL ELBOWS.