Permit: T00CM01645

Parcel: 112021250

Inspection Status: Approved

Inspection History: BUILDING - FINAL

Permit Number - T00CM01645

Inspection Description - BUILDING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
10/01/2000 BUILDING - FINAL Approved IVRS - Inspection 0000*
09/27/2000 BUILDING - FINAL Denied IVRS - Inspection 0999*/1. ELECTRIC OUTLET BY WATER SERVICE LINE OUTSIDE NOT GFCI PROTECTED. 2. KITCHEN GFCI OUTLETS INOP. 3. GARAGE DOOR DOES NOT SELF CLOSE. 4. FIRE CAULK GAS LOG LIGHTER PENETRATION. 5. BARE BULB FIXTURES NOT ALLOWED IN CLOTHES CLOSET. 6. STAIR REQUIRES HAND RAIL. 7. NEED INSULATION AND STUCCO INSTALLATION CERTIFICATES.