Permit: T00CM01622

Parcel: 132169280

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T00CM01622

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
12/07/2001 FRAMING Approved IVRS - Inspection 0000*
03/28/2001 FRAMING Partial Approval IVRS - Inspection 0000* STUCCO LATH APPROVED
03/09/2001 FRAMING Partial Approval IVRS - Inspection 0000* 1) BRACE MAN DOORS, IN EXTERIOR WALLS, PER THE DETAIL ON PAGE 119 OF "MID-WEST STEEL BLDG CO." DETAIL AND SAFETY MANUAL 2) ADJUST SWAY BRACE IN SOUTH WALL OF BLDG. THE CABLE BEARS ON THE WRONG SIDE OF THE "EYE". 3) ADJUST THE HILL SIDE WASHER AT THE CABLE IN THE ROOF. HILL SIDE HAS SLID OUT OF PLACE. THE BUMP NOT IN SLOTTED HOLE
4) PROVIDE BACKING FOR H.C. BARS IN TOILET ROOMS 5) COMPLETE PLUMBING, ELEC., AND MECH. INTERMEDIATES.