Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 01/09/2002 |
BUILDING - FINAL |
|
Approved |
IVRS - Inspection 0000* |
| 12/07/2001 |
BUILDING - FINAL |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) NEED HOUSE ADDRESS 2) PAINT VTR WITH LATEX 3) COMPLETE CLEANOUT AT WEST WALL 4) ELECTRIC AT CONDENSATE 5) COMPLETE ALL PLUMBING |
| 12/04/2001 |
BUILDING - FINAL |
|
Denied |
IVRS - Inspection 0999*/ 1) CUT CLEANOUTS TO FINISH GRADE AND CAP 2) CLEANOUT WEST WALL NEEDS TO BE CUT AND CAPPED 3) SEAL AROUND WATER HEATER FLUE PIPE 4) IDENTIFY ALL CIRCUITS AT PANEL 5) ALL HOSE BIBS REQUIRE VACUUM BREAKERS 6) OUTLET LEFT OF REFRIGERATOR NOT GFCI 7) BOTH OUTLETS ON ISLAND MUST BE ON GFCI 8) SMOKE DETECTOR NEEDS TO BE HOOKED UP TOGETHER |
| 08/22/2001 |
BUILDING - FINAL |
|
Not ready for Inspection |
IVRS - Inspection 0000* |