Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/29/2000 | PLUMBING - FINAL | Approved | IVRS - Inspection 0000* ALL CORRECTIONS MADE RPBP CERTIFICATION OK OK FOR C OF O PENDING ANY OTHER INSPECTIONS |
|
| 09/26/2000 | PLUMBING - FINAL | Denied | IVRS - Inspection 0999* 1. NEED TO SEE CERTIFICATION FOR RPBP 2. NO FITTING MAY BE TIED IN BETWEEN METER AND RPBP 3. L-4 INDICTES IRRIGATION BACKFLOW PREVENTER TO BE TIED IN ON BLDG SIDE OF RPBP 4. NEED TO SEE RED LINE "AS BUILT" SHOWING RELOCATION OF WATER SERVICE, AND NORTH SIDE HOSE BIBB 5. KITCHEN SINK P-TRAP BACK PITCHED TO TRAP ARM 6. ADA URINAL 17" AFF MAX STANDARD URINAL 24" MAX 7. CRITICAL LEVEL ON FLUSHOMETER MINIMUM 6" 8. THIS LIST MAY NOT INCLUDE ALL CODE VIOLATIONS CHECK YOUR WORK |