Permit: T00CM01485

Parcel: 113051680


Addresses:

3461 N WILSON AV

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
10/30/2000 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*/NOTE: ELECTRIC REQUIRES GROUND MAKE. OK TO INSULATE AND DRYWALL.
08/08/2000 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection 0000*/1. REVISED FIRE PLATE MUST BE APPROVED BY CITY OF TUCSON. 2. USE OF 4 2 X 4 COLUMNS INSTEAD OF 4 2 X 4 PER 3/A8 MUST BE APPROVED BY CITY OF TUCSON. 3. TRIPLE 2 X 12 HEADER IS REQUIRED TO BEAR ON 3 2 X 6 POST NOT DOUBLE 2 X 4. 4. ENTRY REQUIRES 6 X 10 BEAM. 4 X 10 USED BUILD TO PLAN OR REVISE PLAN TO AS BUILT AND HAVE QPPROVED BY C. O. T. OK TO DRY IN ROOF AND EXTERIOR