Permit: T00CM01449

Parcel: 133146610

Inspection Status: Correction Required

Inspection History: PLUMBING - ROUGH, SOIL

Date Description Inspector Results Comments
03/31/2000 PLUMBING - ROUGH, SOIL Correction Required ADDTL COMMS - 1. ALL CORRECTIONS HAVE BEEN MADE 2. OK TO BACKFILL TRENCH
03/28/2000 PLUMBING - ROUGH, SOIL Correction Required ADDTL COMMS - 1. SOIL WATER TEST OK 2. OK TO BACKFILL TRENCH 3. DO NOT COVER P.O.C. OF NEW 3 BLDG DRAIN TO EXSITING BLDG DRAIN. 4. MUST REMOVE 3 TEST TEE @ P.O.C. NO THREADED FITTINGS CAN BE UNDERSLAB 5. MUST USE SPECIALTY COUPLING ON 2 VENT @ MOP SINK IN MECH RM. 6. WILL REQUIRE REVISED AND APPROVED DRAWING FOR WASTE AND VENT SYSTEM BEFORE FINAL 7. OK TO DRYWALL 8. SPECS CALL FOR WASTE AND VNET SYSTEM TO BE CAST IRON NO HUB.
03/28/2000 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection 0000*