Permit: T00CM01393

Parcel: 124081030


Addresses:

317 N VINE AV 02

Inspection Status: Approved

Inspection History: ELECTRIC - CABLE DROP

Date Description Inspector Results Comments
04/13/2001 ELECTRIC - CABLE DROP Approved IVRS - Inspection 0000*
04/09/2001 ELECTRIC - CABLE DROP Denied 1.) NEED GRI RECEPTACLE IN BATHROOM 2.) MISSING GROUND AT BATH LIGHT 3.) LABEL BREAKERS 4.) GROUND SWITCHES 380-9 5.) GROUND NOT TO HAVE MORE THAN ONE WRAP AROUND SCREW AND TO BE INSTALLED IN A CLOCKWISE DIRECTION 6.) WATER HEATERS TO HAVE A DISCONNECTING MEANS 7.) LABELS A/C DISCONNECTS 8.) CORRECTLY CONDUCTOR 9.) FRONT RECEPTICAL TO BE GFI.