Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Correction Required
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T00CM01364
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Correction Required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/13/2000 | EXT METAL CLIPS/EXT SHEATHING | Correction Required | ADDTL COMMS - DENIED - STOPPED INSPECTION. 1. NO LOT NUMBERS POSTED. 2. EAST AND SOUTH WALLS ARE COVERED WITHOUT APPROVAL. UNCOVER. 3. NO CITY OF TUCSON APPROVED TRUSS DRAWINGS. 4. STUBBED TRUSSES MUST BE SOLID. BLOCKED AT TOP AND BOTTOM CHORD. 5. OSB SHEAR IS NOT NAILED OR EDGES PROPERLY SUPPORTED. 6. NEXT TIME WORK IS COVERED WITHOUT APPROVAL YOU WILL BE CHARGED A RE-INSPECTION FEE. | |
04/13/2000 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection 0999* |