02/08/2001 PLUMBING - INTERMEDIATE Approved IVRS - Inspection 0000* 1) WASTE AND VENT SYSTEM OK 2) ALL CORRECTIONS HAVE BEEN MADE 3) OK TO DRY WALL UPON BLDG INSP APPROVAL
02/06/2001 PLUMBING - INTERMEDIATE Denied IVRS - Inspection 0999*
MUST USE SPECIALTY COUPLINGS WHEN TRANSITION IS MADE FROM ABS TO C.I.
MUST HAVE DIRECTIONAL FITTINGS WHEN EXTENDING C.O.
2" HORIZONTAL VENT EXCEEDS MAX DISTANCE FOR FLOOR SINK AT SODA FOUNTAIN
MUST HAVE REVISED AND APPROVED BEFORE NEXT INSPECTION
MUST HANG ABS HORIZONTAL VENTS EVERY 4'-0"
P.O.C. OF BLDG DRAIN TO BLDG SEWER OK
12/21/2000 PLUMBING - INTERMEDIATE Partial Approval RE ALIGNMENT OF P-1 OK
2" COPPER WASHER SERVICES STUBED INTO BUILIDNG OK