Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 06/22/2001 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 03/27/2001 |
FRAMING |
|
Not ready for Inspection |
IVRS - Inspection 0000* |
| 03/23/2001 |
FRAMING |
|
Not ready for Inspection |
1. 1/5 OF PLAN WALLS FOR DOUBLE TOP PLATES WALL BUILT UP WITH 7-2 X 6 TOP PLATES PROVIDE ARCHITECT AND CITY APPROVED DETAIL FOR PLATE TO WALL CONNECTIONS/AS BUILT. 2. 6 X 12 BEAMS ARE BEARING ON BUILT UP POSTS ON NORTH WALL THAT ARE SPLICED AT 8+ FOOT LEVEL AND BEARING ON SINGLE 2 X 4 STUDS AT 16" O.C. ON SOUTH WALL. 3. RAFTERS ON OVERBUILT AREA MUST BEAR ON 2X SLEEPERS/VALLEY BOARDS THE WIDTH OF RAFTERS CUT. 2 X 8 NOTE 7. |