Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T00CM01151
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/15/2001 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection 0000* 1) NEED TO SEE FIRST FLOOR CLOSET RINGS 2) REMEMBER PLUMBERS TAPE IA NOT APPROVED FOR MEETING MINIMAL STRAPPING REQUIREMENTS | |
02/14/2001 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection 0999* 1) WHERE VENTS CONNECT TO A HORIZONTAL DRAIN THE VENT INVERT MUST BE ABOVE THE DRAINAGE CENTERLINE | |
02/12/2001 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection 0999* NEED TO PROVIDE AT LEAST MINIMAL SUPPORT AND BRACING ON DRAINS AND WATER LINES. | |
02/09/2001 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection 0000* | |
02/08/2001 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection 0000* |