Permit: T00CM01151

Parcel: 11626273F


Addresses:

41 S SHANNON RD 12


Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T00CM01151

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
02/15/2001 PLUMBING - INTERMEDIATE Approved IVRS - Inspection 0000* 1) NEED TO SEE FIRST FLOOR CLOSET RINGS 2) REMEMBER PLUMBERS TAPE IA NOT APPROVED FOR MEETING MINIMAL STRAPPING REQUIREMENTS
02/14/2001 PLUMBING - INTERMEDIATE Denied IVRS - Inspection 0999* 1) WHERE VENTS CONNECT TO A HORIZONTAL DRAIN THE VENT INVERT MUST BE ABOVE THE DRAINAGE CENTERLINE
02/12/2001 PLUMBING - INTERMEDIATE Denied IVRS - Inspection 0999* NEED TO PROVIDE AT LEAST MINIMAL SUPPORT AND BRACING ON DRAINS AND WATER LINES.
02/09/2001 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection 0000*
02/08/2001 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection 0000*