Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T00CM01101
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/14/2001 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection 0000*1.) ALL CORRECTION MADE OK 2.) OK TO COVER WALLS. | |
11/08/2001 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection 0000*1.) WATER TEST OK 2.) TRAP ARM OK OK 3.) CLOSET FLANGE OK 4.) SUPPORT VERTICAL ABS. 5.) N/H BANDS NOT APPROVED FOR ABS. 6.) REPLACE N/H BANDS AND RE-TEST. | |
11/02/2001 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection 0999*1.) PLUMBING YARDWATER OK FROM METER TO BLDG. NO CONNECTIONS TO BE MADE BETWEEN METER AND RPBP. 2.) INSTERMEDIATE 1.) THE TRAP ARM SHALL BE THE SAME SIZE FOR ITS. DEVELOPED LENGTH. 2.) NO CLOSET RING. 3.) NO VTR. 4.)NO WATER TEST. |