Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING PRE-SLAB
Permit Number - T00CM01083
Inspection Description - BUILDING PRE-SLAB
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/29/2002 | BUILDING PRE-SLAB | Approved | IVRS - Inspection 0000* | |
04/26/2002 | BUILDING PRE-SLAB | Denied | IVRS - Inspection 0999*1.) 13 1/2' @ HIGH END OF LOWER SECTION AND APPROXIMATELY 10' NEAR CENTER OF NEWLY FORMED LOWER SECTION DOES CONFORM TO UBC 107.7.3.1 FOR MINIMUM COVER. PLEASE PROVIDE RFI FOR REPAIR. 2.) THE BARS IN QUESTION ARE ALONG OUTSIDE EDGE @ BASE OF BARRIERS. | |
04/25/2002 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection 0000*BARRIER TOP 40 & BOTTOM 40 OK. | |
04/24/2002 | BUILDING PRE-SLAB | Partial Approval | UPPER SECTION OF BARRICADE OK. LOWER SECTION NOT READY. | |
04/19/2002 | BUILDING PRE-SLAB | Denied | IVRS - Inspection 0999*1.) PROVIDE 1 1/2" CLEARANCE FROM EXPOSED EDGES OF CONCRETE 2.) CLEAR RUBBLE FROM FOOTER 3.) PROVIDE 3" CLEAR CAST AGAINST. | |
03/01/2002 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection 0000*EAST APPROACH 1.) FORMS NOT YET IN PLACE BUT STEEL GENERALLY CONFORMS TO PLAN. NEED TO ADD RINGS VERTICALS AT EACH SIDE OF LIGHT BOXES. | |
02/21/2002 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection 0000*REBAR PLACEMENT OK BY FAX TERRACEN REPORT ON EPOXY. LEFT MESSAGE WITH DAVE @ TERRACON PROVIDING FIELD REPORT.S | |
02/15/2002 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection 0000*MSE CAP @ EAST APPROACH. 1.) MET WITH RICK NOWAK OF MARTIN & WHITE THEY ARE OUT DETAILS OF DOING MONOPOUR FOR ENTIRE CAP. 2.) VERTICALS 6" TOO SHORTLY A LONG EXTERIOR OF BARRIER, MAY BE SPLICED IN WHEN BARRIER POURED 3.) MATT TOO LOW BEING ADDRESSED BY RICK NOWAK. | |
02/08/2002 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection 0000*TOP LIFT WEST APPROACH. | |
02/01/2002 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection 0000*I NEED SPECIAL INSP. REPORTS FOR H.LT. ANCHORS I STILL NEED ALL SPECIAL INSP. REPORTS FOR EAST APROACH. | |
11/05/2001 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection 0000*BRIDGE SECTION 1-5 OK TO POUR. | |
11/02/2001 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection 0000*SECTION 1-5 | |
08/29/2001 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection 0000* | |
08/14/2001 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection 0000*BRIDGE BEAMS 7-10 |