Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
Permit Number - T00CM01024
Inspection Description - ELECTRIC - FINAL
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/24/2001 | ELECTRIC - FINAL | Approved | IVRS - Inspection 0000* | |
| 09/19/2001 | ELECTRIC - FINAL | Partial Approval | IVRS - Inspection 0000*PARTIAL CALL FOR FINAL WHEN UNIT IS ENERGIZED & READY FOR "HOT" TEST. | |
| 09/11/2001 | ELECTRIC - FINAL | Partial Approval | IVRS - Inspection 0000*1.) UPSTAIRS BATH ROOM LIGHT, FIXTURE NEEDS TO BE OVER COMPLETE OUTLET BOX BOTH BATH ROOMS UPSTAIRS 2.) INSTALL LIVING ROOM RECEPTACLE. 3.) SOME #14 WIRE CIRCUITS ON 20 AMP BREAKERS 4.) INSTALL PANEL AND LABEL CIRCUITS 5.) FINISH KIT EXHAUST FAN OUTLET. 6.) PLAN HAVE BEEN CHANGED LOCATION OF CIRCUITING IN KITCHEN DOES NOT MATCH. 7.) KITCHEN COUNTER RECEPTACLE ON NORTH WALL, NEED TO BE SPACED OUT 48" FROM EACH OTHER. 8.) LB'S AT SERVICE CANNOT HAVE COVER BURRIED IN GROUND 9.) FINISH AC ON ROOF. 10.) SEAL OUTSIDE SURFACES ON LIGHTS. RECEPTACLES SO WATER DOES NOT ENTER. | |
| 09/10/2001 | ELECTRIC - FINAL | Denied | IVRS - Inspection 0999* |