Permit: T00CM00977

Parcel: 116274700


Addresses:

3477 W TINY BIRD CT


Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T00CM00977

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
11/15/2000 FRAMING Approved IVRS - Inspection 0000*
11/08/2000 FRAMING Denied IVRS - Inspection 0999*/GAS LINE OBSTRUCTING ATTIC ACCESS AT FURNACE AREA. 2. SECURE GAS LINE PER UPC TABLE 12-3. 3. PROVIDE COMBUSTION RELIEF TO BOTH FURNACES "LOWER" 4. #2 WALL REQUIRES 1/2" ANCHOR BOLT AT 32" O.C. PER PLAN 5. PROVIDE OHA 6. SMITH PANS NOT PROVIDED. 7. STRAP HDR AT MAST. WATER CLOSET. 8. CHECK ANCHOR BOLTS THRU OUT 9. STRAP BEAM AT ENTRY. 10. FIRE BLK CLOSETS AND THRU OUT. 11. EXHAUST VENT NOT THRU ROOF. 12. EXHAUST DUCT AT LAUNDRY NEEDS TO BE COMPLETELY REDONE.
11/07/2000 FRAMING Denied IVRS - Inspection 0925*/NO PLANS OR PERMIT CARD ON SITE. NO GAS TEST.
11/06/2000 FRAMING Cancelled IVRS - Ri canceled
11/01/2000 FRAMING Denied IVRS - Inspection 0999*/1. PROVIDE 1" CLEARANCE FROM COMUBSTIBLES AT ALL FLUE PIPES. 2. PROVIDE 120V TO HOT WATER RECIRCULATING MOTOR. 3. PROVIDE CLEAN OUT AFTER LAUNDRY TRAP. 4. DISCHARGE LINE FOR WATER SOFTENER CAN NOT CROSS CONNECT PROVIDE 1" GASP. 5. SUPPORT ALL SHOWER SIVERTERS. 6. HIGH CONDENSATION NOT INSTALLED FROM SMITTY PAN. 7. PROVIDE MIN. 30" WORK SPACE IN FRONT OF FURNACE AND REMOVE ALL OBSTRUCTIONS TO 30" HIGH. SEE MP 1-M FOR INSTRUCTIONS. 8. COMPLETE DRAFT STOP AT FIREPLACE, STRAP ALL 45 DEGREE FLUE SECTIONS. COMPLETE GAS LINE INTO FIRE PLACE AND TEST. COMPLETE 120V POWER TO FIRE PLACE. ALL DRAFT STOPS USING OSB MIN 2 PLY. 9. PROVIDE CLEAN OUT AT CHICAGO LOOP FOOT VENT. 10. ELIMINATE ONE 90 DEGREE ELBOW AT LAUNDRY FURNACE FLUE. 11. PROVIDE APPROVED LISTING FOR PLASTIC CEILING FAN BOXES. 12. BLOCK ALL MECHANICAL 3 SIDES. 13. PROVIDE FIRE BLOCKS AT HALL BATH BEHING LAUNDRY. 14. PROVIDE A LADDER TO INSPECT UPPER LEVELS. 15. PROVIDE COMBUSTION/RELIEF AS PER SHEET MP A CM AND PER U.M.C. FOR BOTH ATTIC FURNACE.