Permit: T00CM00951

Parcel: 136327510

Inspection Status: Correction Required

Inspection History: FRAMING

Date Description Inspector Results Comments
04/10/2000 FRAMING Correction Required ADDTL COMMS - APPROVED - COMPLETE UTILITY ROOM DROPPED CEILING AND FIREBLOCK.
04/07/2000 FRAMING Partial Approval IVRS - Inspection 0000*
04/06/2000 FRAMING Correction Required ADDTL COMMS - DENIED - STOPPED INSPECTION - COMPLETE AND RECALL. 1. DRYER DUCT IS EXPOSED IN LAUNDRY ROOM. 2. BOLT AND CLIP INTERIOR BEARING WALLS AND TRUSSES. 3. PA TO BE ON DOUBLE STUD FULL HEIGHT. 4. SHEARWALL TRANSFER IS INCOMPLETE. 5. MECHANICAL IS INCOMPLETE. 6. ATTIC ACCESS EXCEEDS 20 FEET TO UNIT. 7. SUPERINTENDENT TO WALK ALL JOBS PRIOR TO INSPECTION REQUEST. MAKE PUNCH LIST. HAVE SUB-CONTRACTPR CORRECT ITEMS THEN CALL FOR INSPECTION.
04/06/2000 FRAMING Denied IVRS - Inspection 0999*