Inspection Status: Partial Approval
Inspection History: ELECTRIC - INTERMEDIATE
| Date |
Description |
Inspector |
Results |
Comments |
| 12/19/2000 |
ELECTRIC - INTERMEDIATE |
|
Partial Approval |
IVRS - Inspection 0000*/1. GROUND OUTSIDE METAL EL BOX OUTSIDE. 2. WINDOW BY ENTRY MUST BE SAFETY GLAZED. 3. LAUNDRY CRIMP/COPPER. |
| 10/18/2000 |
ELECTRIC - INTERMEDIATE |
|
Denied |
IVRS - Inspection 0999*/HOUSE NOT BUILT TO PLAN STOPPED INSPECTION. 1. WINDOW WITHIN 24" OF DOOR MUST BE SAFETY GLASS. 2. DUCT WORK NOT PER PLAN RIGID AND FLEX COMB. PLAN CALL FOR PLEX. 3. DUCT RADIUS TO TIGHT APPLY TO STANDARDS. 4. LIV. RM CEILING RAFTERS 2 X 10'S EXISTING IS 2 X 4 AT 16' O.C. BUILD TO PLAN OR REVISE TO AS BUILT. 5. NAIL PROTECT ALL WIRE 9. 4 X 6 POST AT ENTRY 6. FIRE BLK ALL CEILING. 7. OUTLET MISSING AT HALL ALCOVE. 8. REROOF. |