Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
Permit Number - T00CM00748
Inspection Description - BUILDING - FINAL
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/11/2001 | BUILDING - FINAL | Approved | IVRS - Inspection 0000* | |
| 06/08/2001 | BUILDING - FINAL | Denied | IVRS - Inspection 0999*/ 1) GUEST HOUSE BATHROOM WINDOW WITHIN 60" OF TUB/SHOWER DRAIN HEIGHT, WINDOWS MUST BE SAFETY GLAZED 2) GRADING NOT COMPLETE 2 PERCENT GRADE AWAY FROM HOUSE 5 FEET REQUIRED 3) NON WEATHER PROOF LIGHT FIXTURES OUTSIDE CANNOT BE INSTALLED TO TRAP RAIN 4) BARE BULB LIGHT FIXTURES NOT ALLOWED IN CLOTHES CLOSETS 5) KITCHEN COUNTER OUTLETS MUST BE ON 2 SEPARATE 20 AMP GFCI PROTECTED CIRCUITS 6) PROVIDE STUCCO AND INSULATION INSTALLATION CERTIFICATES |