Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T00CM00748
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/08/2001 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection 0000* | |
| 12/29/2000 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection 0000*/1. HOLD DOWNS ARE INSTALLED WITH 5/8 AND 3/4" SSTB FOR HD8A. WHICH ARE INSTALLED YOU MUST OBTAIN APPROVAL FROM SIMPSON STRON TIE ENGINEER AND APPROVED BY COT PRIOR TO FINAL INSPECTION. 2. GREAT ROOM RIDGE BEAM AND FIREPLACE SEPARATION RESOLUTION AND PLAN REVISION MUST BE CORRECTED AND REVISED PROCEED AT YOUR OWN RISK. NOTE: FIRE SEPARATION AT FIREPLACE WALL CAVITY ACHIEVED. BEAM SEPARATION/ALTERNATIVE OF 1" MAY BE APPLICABLE PER 2000 IRC R1001. FIGURE R1001.17 CRICKET CRITERIA VARIFY. PULL PROJECT LOCK AND DELETE REFEE. | |
| 12/28/2000 | EXT METAL CLIPS/EXT SHEATHING | Denied | 1. SIMPSON STTB HOLDOWNS BOLTS WERE NOT INSTALLED IN STEM WALL DURING CONSTRUCTION PROVIDE CITY OF TUCSON APPROVED REPAIR. 2. THIS PROJECT MAY HAVE SERIOUS STRUCTURAL DEFICIENCIES AS NOTED IN PAST INSPECTIONS, YOUR PLANS MUST BE REVISED AND APPROVED BY CITY OF TUCSON FOR ALL NOTED ITMES INCLUDING GREATROOM ROOF STRUCTURE, HOLD DOWN ANCHOR BOLTS AND SPARATION FROM MASONRY FIRE PLACE AS WELL AS RIDGE BEAM BEARING ON FIRE PLACE. | |
| 12/27/2000 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection 0999*/1. FOR FIREPLACE CLEARANCE OF 2" YOU MUST HAVE THE REQUIREMENT DELETED WITH A SIGNATURE FROM REYES OR CITY OF TUCSON BUILDING OFFICIAL. 2. HDPA HOLDDOWNS REQUIRE 7/8" BOLTS UNDERSIZED INSTALLED ALL PRIOR ITEMS OPEN. | |
| 12/22/2000 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection 0999*/1. GUEST HOUSE HOLD DOWNS BOLTS MISSING WASHERS, BOLTS LOOSE AND UNDERSIZE EMBEDDED BOLTS. PROVIDE APPROVED REPAIR. 2. MAIN HOUSE HOLD DOWN BOLTS MISSING WASHERS, BOLTS LOOSE AND UNDERSIZED EMBEDDED BOLTS. PROVIDE APPROVED REPAIR. 3. ALL MASONARY AROUND FIREPLACE AND CHIMNEY REQUIRE 2" CLEARANCE TO COMBUSTABLES INCLUDING FRAMING, EXTERIOR SHEATHING, O.S.B. AND BEAM IN BEAM SADDLE. 4. NOTE 20 11/6 NOT COMPLIED WITH. 5. COMPLY WITH ALL PRIOR OPEN ITEMS. 6. HDPA HOLD DOWNS REQUIRE 7/8" SSTD BOLTS 1/2" INSTALLED PROVIDE APPROVED REPAIR. NEXT FAILURE WILL BE CHARGED A REFEE. | |
| 12/07/2000 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection 0000*/NEED ARCH/ENGINEER DETAIL APPROVAL OF RIDGE BEAM AND BEARING POINTS AS BUILT. | |
| 12/05/2000 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection 0999*/1. 2" CLEARANCE REQUIRED ALL AROUND FIREPLACE TO COMBUSTABLES MATERIAL. SEE UBC SECTION 3102.7.8. 2. EXTERIOR WALLS MUST BE TIED TOGETHER WITH RAFTER TIES PER UBC SECTION 2326.12.6. OR PROVIDE A CITY APPROVED DETAIL OF ROOF AND FRONT PORCH SUPPORT. 3. NOTE 20 11/06 NOT COMPLIED WITH. 4. ITEMS 3, 5, 6, 7 OF PRIOR INSPECTION NOT COMPLIED WITH. NOTE: CANNOT APPROVE FRAME UNTIL ALL TRADES COMPLETE. | |
| 12/01/2000 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | ||
| 11/29/2000 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection 0999*/1. 2/A04 AT GARAGE NOT COMPLIED WITH. 2. 15/A06 NOT COMPLIED WITH NOTE 4. 3. PROVIDE DETAIL FOR RIDGE BEAM SUPPORT AT ENTRY ARE COLLAR TIES NEEDED. 4. A35 CLIPS NOT INSTALLED WITH TAB OVER LEDGER FOR SHEAR I SUGGEST YOU ADD A2.5 CLIPS FROM LEDGER TOP TO STUDS. 5. 11/A06 NOT 20 NOT COMPLIED WITH. 6. CODE REQUIRES 2" CLEARANCE FROM MAONARY FIREPLACE TO COMBUSTABLES. 7. PROVIDE DETAIL OF RIDGE BEAM SADDLE CONNECTION IS FIRE PLACE BUILT TO SUPPORT RIDGE BEAM. 8. ONE TRUSS NOT NAILED OVER KITCHEN |