03/13/2000 EXT METAL CLIPS/EXT SHEATHING Correction Required ADDTL COMMS - APPROVED AS NOTED: 1. SHEARWALL TRANSFER AT GARAGE NEEDS TO BE NAILED 4 O.C. AT BOTTOM PLATE TO TOP PLATE WITH 16ds. 2. TC CLIPS ARE NOT NAILED PER MANUFACTURERS SPECS. 3. HOLD-DOWN AT REAR SLIDER NAILED TO TRIMMERS. 4. NO TRUSS CALCULATIONS ON JOB SITE.