Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T00CM00700
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Correction Required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/13/2000 | EXT METAL CLIPS/EXT SHEATHING | Correction Required | ADDTL COMMS - APPROVED AS NOTED: 1. SHEARWALL TRANSFER AT GARAGE NEEDS TO BE NAILED 4 O.C. AT BOTTOM PLATE TO TOP PLATE WITH 16ds. 2. TC CLIPS ARE NOT NAILED PER MANUFACTURERS SPECS. 3. HOLD-DOWN AT REAR SLIDER NAILED TO TRIMMERS. 4. NO TRUSS CALCULATIONS ON JOB SITE. |