Inspection Status: Correction Required
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 04/14/2000 |
FRAMING |
|
Correction Required |
ADDTL COMMS - PARTIAL - BEFORE INSULATING AND DRYWALL, SEAL PENETRATION AT WEEP SCREED TO SOLE PLATE. |
| 04/14/2000 |
FRAMING |
|
Partial Approval |
PARTIAL APPROVAL |
| 04/12/2000 |
FRAMING |
|
Correction Required |
ADDTL COMMS - DENIED - RE-INSPECTION FEE REQUIRED. 1. SEAL PVC ISLAND IN KITCHEN ELECTRICAL. 2. PREVIOUSLY ADVISED. PROVIDE 2 INCH CLEARANCE CHIMNEY FLUE FROM COMBUSTIBLE MATERIAL. 3. NO DETAIL PROVIDED FOR BACK PATIO AS BUILT. PREVIOUSLY ADVISED. YOU NEED CITY OF TUCSON APPROVAL. 4. NO CITY OF TUCSON APPROVED TRUSS CALCULATIONS. 5. NEED 15 LBS MINIMUM PRESSURE GAS LINE. |
| 04/12/2000 |
FRAMING |
|
Denied |
DENIED |
| 04/10/2000 |
FRAMING |
|
Correction Required |
ADDTL COMMS - DENIED - STOPPED INSPECTION. 1. OVER KNOTCHED KITCHEN VTR BEARING STUD. NEED STT OR BANG PLATE. ALSO AT LAUNDRY WATER. 2. BACK PATIO HANGERS ARE NOT NAILED. NEED A REVISED APPROVED DETAIL FOR AS BUILT APPROVED BY CITY OF TUCSON. 3. MECHANICAL IS NOT BLOCKED. 4. PROVIDE CLEARANCE PER MANUFACTURES SPECS. CHIMNEY FLUE. |
| 04/10/2000 |
FRAMING |
|
Denied |
DENIED |