Inspection Status: Correction Required
Inspection History: PLUMBING - INTERMEDIATE
| Date |
Description |
Inspector |
Results |
Comments |
| 06/13/2000 |
PLUMBING - INTERMEDIATE |
|
Correction Required |
ADDTL COMMS - 1. SOIL WATER TEST OK 2. OK FOR CONCRETE PATCH AND DRYWALL |
| 06/06/2000 |
PLUMBING - INTERMEDIATE |
|
Correction Required |
ADDTL COMMS - 1. MUST PROVIDE WATER TEST ON WASTE SYSTEM |
| 06/06/2000 |
PLUMBING - INTERMEDIATE |
|
Not ready for Inspection |
IVRS - Inspection 0000* |
| 05/09/2000 |
PLUMBING - INTERMEDIATE |
|
Denied |
DENIED |
| 05/04/2000 |
PLUMBING - INTERMEDIATE |
|
Correction Required |
ADDTL COMMS - 1. NO TEST ON ABS 2. GAS LINE NOT ANCHORED PROPERLY 3. NOT INSTALLED AS PER PLAN SEE REVISED 05/05/95 |
| 05/04/2000 |
PLUMBING - INTERMEDIATE |
|
Denied |
IVRS - Inspection 0999* |
| 04/17/2000 |
PLUMBING - INTERMEDIATE |
|
Correction Required |
ADDTL COMMS - 1. GAS PRESSURE TEST WAS DOWN TO ZERO LBS 2. YOU CAN NOT MAKE A CONVENTIONAL DRAIN INTO A WET VENT @ WATER CLOSET 3. MUST USE DIRECTIONAL FITTING WHEN EXTENDING A C.O. @ LAV 4. WET VENT FOR A.W. NOT TO CODE VENT RISER MUST BE 3 |
| 04/17/2000 |
PLUMBING - INTERMEDIATE |
|
Denied |
IVRS - Inspection 0000* |