Permit: T00CM00652

Parcel: 122070090


Addresses:

1719 N BELVEDERE AV

Inspection Status: Approved

Inspection History: ELECTRIC - INTERMEDIATE

Date Description Inspector Results Comments
03/09/2001 ELECTRIC - INTERMEDIATE Approved IVRS - Inspection 0000*
03/06/2001 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection 0999*/1. MECHANICAL NOT PER PLAN-REVISE PLAN TO AS BUILT. 2. OUTSIDE ELECTRIC OUTLET NOT ALLOWED ON BATHROOM CIRCUIT. 3. REVISE PLAN FOR ELECTRIC WH. 4. REVISE PLAN FOR ALL OVERSIZED WIRE. 5. SPA MUST BE ON A DEDICATED CIRCUIT. 6. MAKE UP ALL GROUNDS. 7. GROUND ALL METAL ELECTRIC BOXES. 8. FAN BOXES CANNOT BE SUPPORTED/SECURED BY NAILS. 9. YOU CANNOT CHANGE WIRE SIZE IN A CIRCUIT. YOU MUST BUILD TO PLAN OR REVISE PLAN TO AS BUILT AND HAVE APPROVED.