Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date |
Description |
Inspector |
Results |
Comments |
| 02/14/2001 |
EXT METAL CLIPS/EXT SHEATHING |
|
Approved |
IVRS - Inspection 0000* |
| 02/12/2001 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999*/1. MANY AREAS OF ROOF SHEATHING NOT NAILED OR HAVE SHINERS. REMOVE ALL SHINERS. 2. O.S.B. RIPPERS LESS THAN 12" WIDE MUST HAVE EDGES SUPPORTED. 3. BRACED WALL PANELS MUST BE NAILED AT TOP AND BOTTOM AND ALL EDGES AT MAXIMUM 6" SPACING ALSO ALL SPLICES MUST BE BLOCKED AND NAILED. 4. NON OVER LAPPING DOUBLE TOP PLATES MUST BE PROPERLY STRAPPED PER U.B.C. 5. HEADERS MUST BE CLIPPED TO KING STUDS. |