Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
06/07/2001 FRAMING Approved IVRS - Inspection 0000*
06/05/2001 FRAMING Not ready for Inspection IVRS - Inspection 0000*/ 1) FILL SOLIDLY UNDER GIRDER TRUSSES AT BEARING POINTS 2) CLIP AND ANCHOR TO CONCRETE ALL INTERIOR BEARING WALLS 3) MAINTAIN 1" CLEARANCE WOOD FRAMING TO MASONRY OR VERIFY MINIMUM 12" GROUT (SOLID) AND BOLT SAME INTO MASONRY 4) NEED POSITIVE CONNECTION 6 X 8 BEAMS AT BEARING 5) "X" BRACE 1ST AND 3RD TRUSSES THRU OUT 6) STOPPED INSPECTION, CONTRACTOR TO COMPLETE ALL TRADES
06/04/2001 FRAMING Denied IVRS - Inspection 0999*/ 1) CANNOT DO INSPECTION WHILE ROOFERS HOT MOP