Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/09/2004 | FRAMING | Approved | IVRS - Inspection :* | |
| 06/29/2004 | FRAMING | Partial Approval | IVRS - Inspection :*/ 1) PROVIDE DWV WATER TEST PER UPC 7 2) DUCT EXHAUST FANS OUTSIDE 3) PEX AT BATHROOM REQUIRES 12" TO LIGHT | |
| 05/28/2004 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) FIRE BLOCK FURRED OUT WALLS AT KITCHEN SOFFIT 2) SECURE KITCHEN PLUMBING AT 90 DEGREE FITTINGS 3) GROUND ALL METAL ELECTRIC BOXES 4) PROVIDE DWV WATER TEST ON PLUMBING 5) PEX NOT ALLOWED WITHIN 12" OF RECESSED LIGHTS 6) SECURE HOSE BIB LINES 7) NM-B ELECTRIC CABLE CANNOT BE EMBEDED IN CONCRETE AT OUTSIDE LIGHTS 8) PROVIDE GROUND PIG TAILS FOR ALL LIGHT SWITCHES |
|
| 02/02/2004 | FRAMING | Not ready for Inspection | IVRS - Inspection 0000*/ 1) 18" TO 30 AT WASHER RISER-NOT APPROVED 2) 1/4" SLOPE AT TRAP ARMS 3) SECURE AND SUPPORT WATER LINES AT KITCHEN AND HOSE BIBS 4) INSTALL CLEANOUT AT KITCHEN | |
| 04/03/2003 | FRAMING | Not ready for Inspection | IVRS - Inspection 0000* | |
| 08/08/2002 | FRAMING | Not ready for Inspection | IVRS - Inspection 0000* |