Permit: T00CM00549


Addresses:

2402 E MOONRISE PL

Inspection Status: Approved

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
11/15/2000 BUILDING - FINAL Approved IVRS - Inspection 0000*
10/30/2000 BUILDING - FINAL Denied IVRS - Inspection 0999*/1. OUTSIDE HOSE BIB REQUIRES ANTI SIPHON VALVE. 2. IRRIGATION NEUTRAL WIRE MUST BE WHITE OR GRAY. 3. DOUBLE LUGGING OF 2 WIRES ON CIRCUIT BREAKER NOT ALLOWED. 4. WATER HEATER VENT CONNECTOR TO VENT REQUIRES 3 SCREWS. 5. ELECTRIC OUTLETS NOT ALLOWED UNDER COUNTER TOPS WITH OVERHANGS IN EXCESS OF 6 INCHES. 6. FIRE PROOF CAULK REQUIRED AT F/PLACE GAS LOG PENETRATION. 7. INTERIOR FURNACE REQUIRES 100 SQ FEET HIGH AND LOW COMBUSTION AIR PRESENTLY APPROXIMATELY 75 SQ INCHES. 7. KITCHEN PENISULA GFCI EXCEEDS 12" BELOW COUNTER TOP.