Permit: T00CM00525

Parcel: 125060310


Addresses:

721 N OLSEN AV

Inspection Status: Correction Required

Inspection History: FRAMING

Date Description Inspector Results Comments
03/22/2000 FRAMING Correction Required ADDTL COMMS - APPROVED - PLANS MUST BE REVISED TO SHOW STEM WALL AT EAST WALL. OKAY TO CONTINUE. PROVIDE REVISION PRIOR TO FINAL. PORCH POSTS WILL BE REPLACED AFTER STUCCO, PER JOHN RAYMOND.
03/20/2000 FRAMING Correction Required ADDTL COMMS - DENIED - STOPPED INSPECTION. 1. ORIGINAL PORCH POST HAS BEEN REMOVED AND 4X8 BEAM DOES NOT HAVE ANY SUPPORT. BEAM CARRY 5-2X6 RAFTERS WITHOUT SUPPORT. REPLACE POST OR PROVIDE APPROVED CONSTRUCTION DETAIL. 2. PLAN CALLS FOR ORIGINAL 6X 6 POSTS TO REMAIN. POSTS HAVE BEEN REMOVED AND WALLS BALLOON FRAMED. REVISE PLAN TO AS BUILT. 3. EAST WALL WAS TO HAVE BEEN ALL WOOD FRAME, HAS 36 MASONRY STEM WITH 2X6 WOOD FRAME, OVER. REVISE PLAN TO AS BUILT. 4. SOUTH AND WEST WALLS COVERED WITHOUT APPROVAL. REMOVE SHEATHING. ALSO EXPOSE WESTSIDE OF ENTRY. 5. NEXT FAILURE WILL BE CHARGED A RE-INSPECTION FEE.
03/20/2000 FRAMING Denied IVRS - Inspection 0999*
03/16/2000 FRAMING Correction Required ADDTL COMMS - DENIED - STOPPED INSPECTION - RE-SCHEDULE INSPECTION. NO ANSWER AT THE DOOR. COULD NOT LOCATE PLANS OR PERMIT OR PRIOR INSPECTION REPORT. LOCK UP THE DOG FOR NEXT INSPECTION.
03/16/2000 FRAMING Denied DENIED
03/10/2000 FRAMING Denied IVRS - Inspection 0999*