Inspection Status: Correction Required
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 04/10/2000 |
FRAMING |
|
Correction Required |
ADDTL COMMS - APPROVED - SHEARWALL MODIFICATION AT LAUNDRY WAS INSTRUCTED BY JOHN RIVA FOR FIELD MODIFICATION/REPAIR. |
| 04/07/2000 |
FRAMING |
|
Correction Required |
ADDTL COMMS - DENIED - 1. PROVIDE ANCHOR BOLTS PER UBC. 2. INISTALL BLOCKING AT WALLS OVER 10HIGH. 3. CRUSHED DUCT. 4. ELECTRIC SWITCH IN THE ATTIC SHALL NOT FACE UP. 5. REVISION NEEDED FOR MISSED BLOCKS. BACK PATIO. |
| 04/07/2000 |
FRAMING |
|
Denied |
DENIED |
| 04/06/2000 |
FRAMING |
|
Correction Required |
ADDTL COMMS - DENIED - STOPPED INSPECTION. 1. LAUNDRY SHEAR WALLS 3/6 DETAIL 6/SD3 MUST EXTEND TO BOTTOM CHORD OF SCISSOR TRUSS-NOT TO DEAD WOOD. DETAIL 7. 2. PROVIDE BOTTOM CHORD BRACING AT 6 O.C. FOR TRUSSES A01. 3. A/C CONDENSATE NOT PROPERLY SUPPORTED. REVERSE FLOW. 4. 2X6 IN HALL MUST BEAR ON Lu26 HANGER. |
| 04/06/2000 |
FRAMING |
|
Denied |
IVRS - Inspection 0999* |