Inspection Status: Partial Approval
Inspection History: EXCAVATION/LAYOUT REBAR & ZON
| Date |
Description |
Inspector |
Results |
Comments |
| 03/29/2000 |
EXCAVATION/LAYOUT REBAR & ZON |
|
Partial Approval |
IVRS - Inspection 0000* |
| 03/28/2000 |
EXCAVATION/LAYOUT REBAR & ZON |
|
Correction Required |
ADDTL COMMS - DENIED - 1. FRONT PORCH POST AND BEAM CONNECTIONS REQUIRE ALL HOLES FILLED IN SIMPSON HARDWARE. 2. REAR PORCH REQUIRES 2-#4 REBAR EACH WITH POST FOOTER. 3. PORCH RAFTERS MUST ABE CLIPPED TO DOUBLE TOP PLATE. 4. 8040 WINDOW REQUIRES TRIMMERS UNDER HEADER. 5. CLIP HEADERS TO KING STUDS. 6. FAN BOX REQUIRES 2-#12 SCREWS MINIMUM. |
| 03/28/2000 |
EXCAVATION/LAYOUT REBAR & ZON |
|
Denied |
IVRS - Inspection 0999* |