Permit: T00CM00428

Parcel: 129023710


Addresses:

2918 E ARROYO CHICO

Inspection Status: Partial Approval

Inspection History: EXCAVATION/LAYOUT REBAR & ZON

Date Description Inspector Results Comments
03/29/2000 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection 0000*
03/28/2000 EXCAVATION/LAYOUT REBAR & ZON Correction Required ADDTL COMMS - DENIED - 1. FRONT PORCH POST AND BEAM CONNECTIONS REQUIRE ALL HOLES FILLED IN SIMPSON HARDWARE. 2. REAR PORCH REQUIRES 2-#4 REBAR EACH WITH POST FOOTER. 3. PORCH RAFTERS MUST ABE CLIPPED TO DOUBLE TOP PLATE. 4. 8040 WINDOW REQUIRES TRIMMERS UNDER HEADER. 5. CLIP HEADERS TO KING STUDS. 6. FAN BOX REQUIRES 2-#12 SCREWS MINIMUM.
03/28/2000 EXCAVATION/LAYOUT REBAR & ZON Denied IVRS - Inspection 0999*