Inspection Status: Correction Required
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date |
Description |
Inspector |
Results |
Comments |
| 03/21/2000 |
EXT METAL CLIPS/EXT SHEATHING |
|
Correction Required |
ADDTL COMMS - APPROVED - 1. PROVIDE RIDGE BLOCKING PER PLAN. 2. PROVIDE ADDITIONAL DIAGONAL BRACES AT GARAGE ENTRY. 3. ALL TRUSSES ARE OKAY AT THIS TIME. |
| 03/20/2000 |
EXT METAL CLIPS/EXT SHEATHING |
|
Correction Required |
ADDTL COMMS - DENIED - 1. POST TENSION IS NOT PULLED. 2ND INSPECTION WITH SAME RESULTS. 2. ENGINEER SHOULD BE AWARE OF ROOF BEING LOADED PRIOR TO PULLING OF CABLES. PROVIDE ENGINEERS APPROVAL. 3. A RE-INSPECTION FEE WILL BE IMPOSED IF REQUIREMENTS ARE NOT ADDRESSED. 4. HOLD-DOWNS AT REAR ARE NOT NAILED UP. |
| 03/20/2000 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999* |
| 03/10/2000 |
EXT METAL CLIPS/EXT SHEATHING |
|
Correction Required |
ADDTL COMMS - DENIED - STOPPED INSPECTION. 1. HOLD-DOWNS IN FRONT ARE NOT NAILED PER MANUFACTURES SPECS. CANNOT BE NAILED TO TRIMMERS. 2. POST TENSION IS NOT PULLED. |
| 03/10/2000 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
DENIED |
| 03/07/2000 |
EXT METAL CLIPS/EXT SHEATHING |
|
Correction Required |
ADDTL COMMS - NOT READY - CANCELLED BY CONTRACTOR. |
| 03/07/2000 |
EXT METAL CLIPS/EXT SHEATHING |
|
Not ready for Inspection |
NOT READY FOR INSPECTION |